RE: [stella] F8 Bankswitching experiment

Subject: RE: [stella] F8 Bankswitching experiment
From: "Ronen Habot" <rhabot@xxxxxxxxxxxxxxxxxxx>
Date: Fri, 6 Dec 2002 08:12:07 -0500

> Your frame has only 86 scanlines! This would result in a framerate of
> about 180(!) Hz and your TV can't sync to that. So you better increase
> the timer values and/or use T1024T instead of TIM64T.

Understood. Now, I have a question in that matter: How many scan lines should I have?
Reading Kirk's tutorial and the Stella guide I learned that in total I should have 262 scan lines (3+37+192+30). I checked one game using z26 -v9 and noticed that it has 280 scan lines. Why would that be? Shouldn't it have 262?

Thanks,
Ronen. 


******************Legal Disclaimer**************************
"This email may contain confidential and privileged material for the sole use of the intended recipient.  Any unauthorized review, use or distribution by others is strictly prohibited.  If you have received the message in error, please advise the sender by reply email @globespanvirata.com, and delete the message. Thank you."
****************************************************************

----------------------------------------------------------------------------------------------