Re: [stella] FE, 3F, Bankswitching, and Data lines

Subject: Re: [stella] FE, 3F, Bankswitching, and Data lines
From: Adam Wozniak <adam@xxxxxxxxxxxxxxxx>
Date: Wed, 18 Dec 2002 11:05:51 -0800 (PST)
On Wed, 18 Dec 2002, Chad Schell wrote:
> What are you using to generate the timing for when the address lines and 
> data lines are stable?

(not Vern, but here's my guess...)

Assume a rough timing of 1.19 MHz

Watch the address lines for any change.  Assume the first change
is on the rising edge of a clock.
Ignore changes for 420 nS.
Assume the clock falls 420 nS after assumed rise.
Continue ignoring changes for an additional 210 nS.

Repeat.

This should get you close enough.

-- 
Will code for food.       http://cuddlepuddle.org/~adam/resume.html